2015最後一週了, 51週的抽查結果讓各位先參考了, 晚點如果52週報告也出來, 小編再補上, 祝各位新年快樂


Hungary

Category: Lighting chains

Product: Lighting chain

Brand: Unknown

Name: 100L LED (on the packaging) / KARACSONYI EGO (on a label)

Type/number of model: RO-AJK-C17

Batch number/Barcode: 1410380083

OECD Portal Category: 78000000 - Electrical Supplies

Description: Lighting chain with 100 LED lamps (25 red, 25 green, 25 blue, 25 yellow). Packaging: colourful cardboard box.

Country of origin: China

 

Electric shock,
Fire

The cross-sectional area of the external and internal wires is too small and the wires could overheat. The dimensions of the plug are too small. The wire ends soldered to the terminals of the flashing unit and the LEDs are not adequately protected against pulling and twisting. The accessible basic insulated wires can come into contact with sharp edges of the flashing switch and control unit. The insulation provided by the shrink tubing for the lamps is inadequate.

The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Compulsory measures:Withdrawal of the product from the market,
Recall of the product from end users  

Hungary

Category: Lighting chains

Product: Lighting chain

Brand: Unknown

Name: LED LIGHTS (on the packaging) / KARACSONYI EGO (on a label)

Type/number of model: RO-AJK-C019

Batch number/Barcode: 1410380086

OECD Portal Category: 78000000 - Electrical Supplies

Description: Lighting chain with 40 LED lamps. Packaging: colourful cardboard box.

Country of origin: China

Electric shock,
Fire

The cross-sectional area of the external and internal wires is too small and the wires could overheat. The dimensions of the plug are too small. The wire ends soldered to the terminals of the rectifier unit and the LEDs are not adequately protected against pulling and twisting. The accessible basic insulated wires can come into contact with sharp edges of the rectifier unit. The insulation provided by the shrink tubing for the lamps is inadequate.

The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Compulsory measures:Withdrawal of the product from the market,
Recall of the product from end users  