小編今天整理歐盟抽查不合格產品資訊時, 發現這些產品有些在幾乎無法進口, 但這些產品比已宣告符合CE指令, 所以這影響層面非常大, 也會讓廠商錯失很多商機, 以下表格就是第九週抽查到不合格的品目, 供各位參考
6 A12/0278/13 |
Finland |
Category: Electrical appliances and equipment
|
Electric shock The battery charger supplied with the lamp poses a risk of electric shock because the insulation is not sufficient and the clearance /creepage distances between the primary and secondary circuits are not sufficient. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Recall of the product from end users , Withdrawal of the product from the market
|
11 A12/0283/13 |
Finland |
Category: Lighting equipment
|
Electric shock The power supply unit supplied with the LED tape poses a risk of electric shock because the insulation is not sufficient and the clearance /creepage distances between the primary and secondary circuits are not sufficient. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Recall of the product from end users , Withdrawal of the product from the market
|
12 A12/0284/13 |
Hungary |
Category: Lighting chains
|
Burns, Electric shock The product poses a risk of burns, electric shock because: - The cross-section area of the external wires is not sufficient and the wires could consequently overheat. - The wire ends soldered to the terminals of the control unit are not adequately protected against pulling and twisting and live metal parts could consequently become accessible. - The accessible wires have only basic insulation and they come into contact with the sharp edges of the flashing switch and control unit. - The dimensions of the plug are substantially less than required and therefore the user may touch the pin of the plug during connection. - The insulation resistance is not sufficient. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Import rejected at border
|
16 A12/0289/13 |
Hungary |
Category: Lighting chains
|
Burns and Electric shock The product poses a risk of burns and electric shock for the following reasons: - the cross-sectional area of the external and internal wires is less than the minimum requirement. - the wire ends soldered to terminals of rectifying unit and the LEDs are not adequately protected against pulling and twisting. -the accessible wires have only basic insulation and they come into contact with sharp edges of the flashing switch and control unit and, in case of damage, the live metal parts become accessible. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Import rejected at border
|