2014-01-17_170544 42跟43週抽查結果發佈如下, 大部份案例都是電擊危險, 旦最後一個案列是因為線材問題進而會造成電擊危險, 加上線材使用不當, 所以被抓到不符合歐盟LVD 指令, 也就是EN60598-1的標準要求, 這二週的案件內容如下, 供大家參考.....

France

Category: Lighting equipment

Product: Flood light

Brand: Unknown

Name: LED FLOOD LIGHT

Type/number of model: Ref.: FL FLOOD 10/3K (on the packaging),
IP 66 (on the product)

Batch number/Barcode: Unknown

OECD Portal Category: 78000000 - Electrical Supplies

Description: LED flood light intended for outdoor use, 10 W, supplied in cardboard box with red sides.

Country of origin: China

Click on the picture to enlarge

Electric shock

The electrical insulation is not adequate and the product is not adequately earthed. Users are therefore exposed to a risk of electric shock.

The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Voluntary measures: Recall of the product from end users  

Hungary

Category: Lighting equipment

Product: LED floodlight

Brand: PANNONLED

Name: 10W Sensor Reflektor

Type/number of model: 800045

Batch number/Barcode: Unknown

OECD Portal Category: 78000000 - Electrical Supplies

Description: Grey LED floodlight with motion sensor and free wire ends for mains connection. Packaging: cardboard box with label.

Country of origin: China

Click on the picture to enlarge Click on the picture to enlarge

Electric shock

The cable is not properly secured against pulling, twisting and loosening. As a consequence, the cable can be pulled out easily leaving the live wire ends of the cable accessible to the user. The cable insulation is made of PVC which is not suitable for outdoor use. The cable is consequently not protected properly against water penetration.

The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Compulsory measures:Withdrawal of the product from the market,
Recall of the product from end users 