2012年倒數二週的時間下, 在51週時, 確抽查出眾多的燈類產品不合格, 這些產品也都有標示符合CE 但為什麼還是會有基本的安規問題呢? 這值得大家細細思考!!
CE在歐盟雖然是自我宣告, 但不代表只要貼上CE就可以取信市場或消費用, CE報告在市場上品質不一, 這也造就更多的廠家選擇CB或GS來為自己產品加分的原因!!
16 A12/1874/12 |
France |
Category: Lighting chains |
Electric shock The power cable’s earth conductor is cut at the point of entry to the electronic box; it is not connected to any part of the lighting set. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Ban on the marketing of the product.
|
17 A12/1875/12 |
France |
Category: Lighting chains |
Electric shock The power cable’s earth conductor is cut at the point of entry to the electronic box; it is not connected to any part of the lighting set. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Ban on the marketing of the product.
|
25 A12/1883/12 |
Hungary |
Category: Lighting equipment
|
Electric shock and Fire The product poses a risk of electric shock and fire because: · When plugging it into a socket, the user could touch the live pins. · The cross-section area of the core of the internal wires is too small and in case of a short-circuit the internal wires may overheat. · The protective bulb cover can be removed by hand during charging, exposing live parts of the LED panel. · The plastic part near the pins is not sufficiently heat and fire resistant and may catch fire. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Withdrawal of the product from the market and recall of the product from end users.
|
28 A12/1886/12 |
Hungary |
Category: Lighting equipment
|
Electric shock The product poses a risk of electric shock because: · The cable ends are not adequately protected against pulling and twisting. · The accessible basic insulated wires can come into contact with sharp edges of the cable entry. In case of damage to the wires, the live metal conductors become accessible. · The phase and neutral terminals are not identified. If the mains supply is connected incorrectly, live metal parts become accessible. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Withdrawal of the product from the market and recall of the product from end users.
|
有任何需求, 皆可透過E-mail跟我們聯絡或詢求協助