2012年第41週, 於歐盟市場抽查, 發現戶外使用頻率高的Floodlight, 有些產品還是無符合EN60598-1+EN60598-2-5要求, 案中產品於抽查測試中有產品電擊危險及冒火的問題, 於歐盟實驗室判定為不符LVD指令要求, 詳細內容如下表內
21 A12/1575/12 |
Hungary |
Category: Lighting equipment
|
Electric shock and Fire Internal wiring that is not insulated could come loose and cause accessible metal parts to become live. In addition, there is no warning to replace the protective glass in case it breaks: if the product was used without the protective glass, and the bulb exploded, parts of the glowing bulb could ignite flammable materials. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Compulsory measures: Withdrawal of the product from the market , Recall of the product from end users
|