LED產品雖然是目前最節能產品, 但也吸引不少廠家轉型加入照明市場的戰局, 就市場方面而言, 日本、歐洲、中國大陸為目前LED產品前三大應用市場, 且加上日本、美國和西歐人口僅佔市全球1/8 , 卻緊握著全球56%照明產品需求, 銷售到這些國家如何以安全及有信心的被消費用使用, 這都是在考驗產品及製造商的能力, 上述這些國家對LED產品的進口, 有些國家是採取自願性認證, 有些是強制性認證, 但不管如何, 市場抽查機制將會使危險產品從市場消失, 即使這些產品已取得認證也一樣。
選擇信譽及國際知名度高的認證機構可以讓您免除這些問題, 若有任何疑問皆可透過E mail跟我們聯絡
No. Ref. |
Notifying country | Product (Click on the photo to enlarge) |
Danger | Measures adopted by notifying country |
5 0735/12 |
Finland |
Category: Lighting equipment
|
Electric shock The product poses a risk of electric shock because live parts are accessible. The product does not comply with the Low Voltage Directive and the relevant European standard EN 61347.
|
Recall from consumers ordered by the authorities.
|
7 0737/12 |
Hungary 816/2012 |
Category: Lighting chains
|
Electric shock and Fire The product poses a risk of electric shock because: - the wire ends soldered to terminals of the flashing switch and control unit and the LEDs are not adequately protected against pulling and twisting: - the accessible wires have only basic insulation and they come into contact with sharp edges of the flashing control unit. In case of damage, the live metal parts become accessible; - the decorative lighting chain is recommended for outdoor use although it is not protected against moisture. The product poses a risk of fire because the cross-section area of the wires is less than the minimum requirement, thus, they can overheat. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Withdrawal from the market and recall from consumers ordered by the authorities.
|
8 0738/12 |
Hungary 817/2012 |
Category: Lighting chains
|
Electric shock and Fire The product poses a risk of electric shock because: - the wire ends soldered to terminals of the flashing switch and control unit and the LEDs are not adequately protected against pulling and twisting; - the accessible wires have only basic insulation and they come into contact with sharp edges of the flashing control unit. In case of damage, the live metal parts become accessible; - the dimensions of the plug are substantially less than the requirement. During connection the user may touch the pins of the plugs; - the decorative lighting chain is recommended for outdoor use although it is not protected against moisture. The product poses a risk of fire because the cross-section area of the wires is less than the minimum requirement thus they can overheat. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Withdrawal from the market and recall from consumers ordered by the authorities.
|
9 0739/12 |
Finland |
Category: Lighting equipment
|
Electric shock The product poses a risk of electric shock because there is inadequate insulation between live parts and accessible metal parts. The product does not comply with the Low Voltage Directive and the relevant European standard EN 61347.
|
Recall from consumers ordered by the authorities.
|
11 0741/12 |
Finland |
Category: Lighting equipment
|
Electric shock The product poses a risk of electric shock because there is inadequate insulation between live parts and accessible metal parts. The product does not comply with the Low Voltage Directive and the relevant European standards EN 60968 and EN 60598.
|
Recall from consumers ordered by the authorities.
|
12 0742/12 |
Finland |
Category: Lighting equipment
|
Electric shock The product poses a risk of electric shock because there is inadequate insulation between live parts and accessible metal parts. The product does not comply with the Low Voltage Directive and the relevant European standards EN 60968 and EN 60598.
|
Recall from consumers ordered by the authorities.
|
18 0748/12 |
Finland |
Category: Lighting equipment
|
Electric shock The mains transformer supplied with the product poses a risk of electric shock because there is inadequate insulation between live parts and accessible metal parts. The product does not comply with the Low Voltage Directive and the relevant European standard EN 61347.
|
Recall from consumers ordered by the authorities.
|
27 0757/12 |
HUNGARY |
Category: Lighting chains
|
Type of risk: Electric shock and Fire The product poses a risk of electric shock and fire because: - the cross-section area of the external wires is less than required; - the wire ends soldered to terminals of flashing control unit are not adequately protected against pulling and twisting; - the accessible wires have only basic insulation; - the insulation resistance is not sufficient. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
|
Withdrawal from the market and recall from consumers ordered by the authorities.
|