於歐盟 LED 照明產品雖然是熱銷產品,若品質無法跟上市場要求, 最終還是被汰換掉, 歐盟於本週又公告新一波不合格名單, 為了不讓產品及商譽成為泡影, 要特別注意目前手上所持有的證書法規是否有符合歐盟產品法規要求.
24 0612/12 |
Germany |
Category: Electrical appliances and equipment
|
Electric shock The product poses a risk of electric shock because the luminous element is not covered, with a consequent risk of electric shock if the soldered points are touched when the light bulb is screwed in or unscrewed, or if touched while the lamp is on. In addition, no address is provided for the manufacturer or its authorised representative and information such as voltage, frequency and power are missing on the product and no instructions for use or information concerning area of use are provided. The product does not comply with the Low Voltage Directive (LVD).
|
Sales ban and withdrawal from the market ordered by the authorities.
|
|
25 0613/12 |
Germany |
Category: Electrical appliances and equipment
|
Electric shock The product poses a risk of electric shock because - the internal wires reach the cooling body through holes which have not been de-burred. This creates a risk of the wires being damaged by the sharp edges; - under a test voltage of approx. 1 000V AC between the lamp holder and the touchable cooling body there is a flow of current (breakdown). The insulation between electrically active parts and metallic touchable parts is thus inadequate; - according to the manufacturer's information this is a light bulb for use outdoors. The stated type of protection (IP 55) cannot be complied with by the open cooling body with the internal wires. Consequently, in the case of water ingress (which can be expected), there is a risk of electric shock; - it is possible to touch the internal wires or the terminal connections on the cooling body with the fingers. In addition, the light bulb weighs approx. 1 kg (by way of comparison, a normal light bulb weighs only approx. 30 g). Consequently, the light bulb engenders a high tensile and/or bending load on the lamp holder. In addition, there is no declaration of conformity by the EU distributor, no address given for the manufacturer or its authorised representative, no CE mark and no information on type designation, voltage, power, frequency or instructions for use. The product does not comply with the Low Voltage Directive (LVD).
|
Sales ban and withdrawal from the market ordered by the authorities.
|
|
26 0614/12 |
Germany |
Category: Electrical appliances and equipment
|
Electric shock and Fire The product poses a risk of electric shock because it can only be used if the existing light fitting is modified. Modifying the light fitting creates hazards for users as it is not possible to ensure, for example, that the necessary insulation distances are observed. No instructions are provided on how to install the tube lights/modify the light fittings. Replacing the LED tube light with a fluorescent tube can cause a short circuit. In addition, no complete address provided for manufacturer or authorised representative, no information on the product, such as CE mark, type designation, voltage, power, frequency is provided. The product does not comply with the Low Voltage Directive (LVD).
|
Sales ban and withdrawal from the market ordered by the authorities.
|
|